Search results for "Artificial lung"

showing 2 items of 2 documents

Accuracy of delivered versus preset minute ventilation of portable emergency ventilators.

1989

The accuracy of delivered minute volume (VE) ventilation of portable emergency ventilators (PEV) was evaluated. Five PEV from three manufacturers were adapted to an artificial lung for varying compliance and resistance. Each PEV was tested in the "no airmix" (pure oxygen) and "airmix" (approximately 60% oxygen) setting at different frequencies and VE. Measurement of delivered VE (VEdel) was made using a pneumotachograph and digital integration of the flow values greater than 1 min (maximal error +/- 2%). Maximal inspiratory pressure (Pinsp) was measured with a transducer. Two PEV from one manufacturer produced severe hyperventilation when used at low VE (i.e., in children). Two other PEV fr…

Adultmedicine.medical_specialtyPure oxygenCritical Care and Intensive Care MedicinepCO2Artificial lunglaw.inventionlawHyperventilationmedicineHumansHyperventilationChildVentilators Mechanicalbusiness.industryHypoventilationSurgeryHypoventilationEvaluation Studies as TopicAnesthesiaVentilation (architecture)Arterial bloodmedicine.symptomEmergenciesbusinessRespiratory minute volumeCritical care medicine
researchProduct

Development of a self-pumping extracorporeal blood oxygenation device characterized by a rotating shaft with embedded fiber packages.

2019

Introduction: To offer respiratory support for patients with lung disease, a novel technological solution for blood pumping and oxygenation is being developed. The pump–lung system was designed to integrate fiber membranes into six packages radially embedded in a rotating hollow shaft placed along the longitudinal axis of the device. Fiber packages are inclined with respect to the rotation axis so that the rotational motion of the rotating shaft allows a self-pumping system to be obtained. Method: Both hemodynamic and gas transfer performances were investigated using both in vitro experiments and in silico flow analyses. Results: The predicted flow velocity in the pump chamber was smooth an…

Lung Diseaseslung disease0206 medical engineeringBiomedical EngineeringMedicine (miscellaneous)Bioengineering02 engineering and technology030204 cardiovascular system & hematologyHeart-Lung MachineExtracorporealArtificial lungBiomaterials03 medical and health sciences0302 clinical medicineMedicineHumansComputational analysisFiberLungartificial lungOxygenators Membranebusiness.industryRespiratory supportHemodynamicsGeneral MedicineOxygenationEquipment Design020601 biomedical engineeringRespiratory supportOxygencomputational analysiLung diseaseBlood oxygenationArtificial OrgansbusinessBiomedical engineeringThe International journal of artificial organs
researchProduct